ResourcesTechnical Articles
Reading a VDI 2230 tightening torque table
A tightening torque table looks like a lookup — find the thread, read the number. In practice the value printed in the table is the end point of a chain of assumptions: friction class, strength grade, yield utilisation and the assembly method used to reach the preload.
Torque is only a proxy for preload. Roughly ninety per cent of the input at the wrench is consumed overcoming friction under the head and in the thread, and only the remainder becomes clamp force. That is why the friction coefficient μ decides the outcome: moving from μ = 0.14 to μ = 0.10 shifts the required torque by close to thirty per cent at the same preload, and a coated fastener assembled dry can overshoot the intended clamp force by the same margin.
MA at μ = 0.10 and MA at μ = 0.14 are the two columns most specifications actually use. Grade 12.9, coarse thread, indicative values:
| Thread | MA at μ = 0.10 | MA at μ = 0.14 | FM (approx.) |
|---|---|---|---|
| M10 × 1.5 | 47 N·m | 61 N·m | 38 kN |
| M12 × 1.75 | 81 N·m | 105 N·m | 56 kN |
| M16 × 2.0 | 158 N·m | 205 N·m | 106 kN |
| M20 × 2.5 | 243 N·m | 315 N·m | 167 kN |
| M24 × 3.0 | 420 N·m | 545 N·m | 241 kN |
Indicative values for illustration. Request the current revision of the certified data sheet for contractual use.
The second thing worth reading in a torque table is what it does not print: the scatter band. Every tightening method has one. A calibrated torque wrench holds the target preload within roughly ±15–20% under controlled conditions; angle-controlled tightening reaches ±7% or better, and hydraulic tensioning removes thread friction from the equation altogether. VDI 2230 sizes the bolt for the maximum preload a method can produce and verifies service loads against the minimum, so the scatter band — not the nominal torque — decides whether the joint is safe.
That leads to the practical rule: specify the pair, not the number. A drawing that states only a torque value leaves the friction condition open, and two suppliers working with different coatings will deliver two very different clamp forces from the same figure. Stating the friction class alongside the torque makes the requirement executable, and it gives incoming inspection something concrete to verify against.
Where assemblies demand preload certainty beyond what torque control can deliver, the usual route is a tensioning system — studs with tension nuts and hardened washers, sized so that elongation rather than friction defines the clamp force. We supply both routes and document them the same way, with batch records covering dimensional, mechanical and coating results.